MAGNET POWER SUPPLY SYSTEM 9100
8
DANFYSIK A/S - DENMARK.
Interlock status
Over voltage
Over current
Over temperature
Fan fault
Earth leakage
AC fault
Out of regulation
External interlock (ext. 1 4)
Summary interlock
COOLING
Water: 1 l/min @ max. Inlet temperature 35° C
Differential pressure: 1 bar
Test pressure: 15 bar
TEMPERATURE RATINGS
Operation Ambient temperature: 15 - 40° C
Storage temperature: -20 - 70° C, non-condensing
CABINET LAY-OUT
Material: Steel
Dimensions W x D x H: 482 mm x 550 mm x 132.5 (3U)
19 inch rack mount
Weight 32 kg (shipping weight 35 kg)
NORMS
Immunity for industries: EN/IEC 61000-6-2:2005
Emission for industries: EN/IEC 61000-6-4:2007
Harmonic Emission (single phase): EN/IEC 61000-3-2:2000
Harmonic Emission (three phase): EN/IEC 61000-3-12:2005
Electromagnetic compatibility: EN/IEC 61000-3-11:2000
Safety req. for electrical equipment: EN/IEC 61010-1:2001

Table of Contents