DIS User Manual
User Manual CU 6105.docx
Note: If only one chain is used the information in section
‘5.3.1 Connection using only one DCS-LAN ’ must be used.
5.3.2.1 DC 6120 P, DC 6190 P or DM 6680
P Conference Units
Feeding Cable
Type CAT5e
AWG24
connecting
Cable, Type
CAT5e AWG24
of units for
both outputs
10 m 1 m 2x32 m 2x23
50 m 1 m 2x70 m 2x21
100 m 1 m 2x117 m 2x18
150 m 1 m 2x164 m 2x15
50 m 2 m 2x88 m 2x20
100 m 2 m 2x132 m 2x17
Figure 5.3-I DC 6120 P, DC 6190 P or DM 6680 P
Conference Units connected
5.3.2.2 DC 6990 P Conference Units
Feeding Cable
Type CAT5e
AWG24
connecting
Cable, Type
CAT5e AWG24
50 m 1 m 2x62 m 2x13
100 m 1 m 2x110 m 2x11
30 m 2 m 2x54 m 2x13
50 m 2 m 2x90 m 2x12
Figure 5.3-J DC 6990 P Conference Units connected
5.3.3 Connection using JB 6104
Junction Box
This following table’s shows conference units
connected to JB 6104 Junction Boxes with 3m cables
between each Junction Box
Important:
* Connect only one unit to each output of a JB 6104.
* Use maximum 5 m cable from JB 6104 to the conference
unit.
5.3.3.1 DC 6120 P, DC 6190 P or DM 6680
P Conference Units, two units per
box
Feeding Cable
Type CAT5e
AWG24
Cable
between
each JB 6104
Type CAT5e
of
JB 6104
(two
outputs in
number of
DC 61xxP
10 m 3 m 61 m 18 36
100 m 3 m 127 m 10 20
150 m 3 m 168 m 7 14
Figure 5.3-K DC 6120 P, DC 6190 P or DM 6680 P
Conference Unit connected using JB 6104
Junction Box, using only two outputs connection
two unit
5.3.3.2 DC 6120 P, DC 6190 P or DM 6680
P Conference Units, four units
per box
Feeding Cable
Type CAT5e
AWG24
Cable
between
each JB 6104
Type CAT5e
AWG24
of
JB 6104
(four
outputs in
use)
number of
DC 61xxP
10 m 3 m 40 m 11 44
30 m 3 m 57 m 10 40
100 m 3 m 115 m 6 25
150 m 3 m 159 m 4 16
Figure 5.3-L DC 6120 P, DC 6190 P or DM 6680 P
Conference Unit connected using JB 6104
Junction Box, using all four outputs connecting
four unit