EasyManua.ls Logo

Dantherm DanX 1 - 9.7 Technical Data DanX 1

Dantherm DanX 1
56 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
9. APPENDIX
51
9.7 Technical data DanX 1
General
Air volume range high speed m
3
/h 500 1250
Air volume nominal m
3
/h 1000
Supply air filter F7 / ePM1 55%
Exhaust air filter M5 / ePM10 70%
Heating coil RR 2 / 3
Coil connection 3/8
Drip tray connection 1
DanX 1 XD
Length mm 1570
Width mm 515
Height mm 1750
Weight kg 254
Electrical connection V 1 x 230 + N
Max full load current A 5.0
Max. power consumption kW 1.2
Max. main fuse A 10
DanX 1 HP
Length mm 1570
Width mm 515
Height mm 1750
Weight kg 279
Refrigerant kg 1.0 / R407c
GWP 1653
PED 1
Electrical connection V 1 x 230 + N
Max full load current A 8.7
Max. power consumption kW 1.9
Max. main fuse A 10

Table of Contents