CODABAR ENTER/EXIT PROGRAMMING MODE
PRODUCT REFERENCE GUIDE   
169
Codabar Set Length 2
This feature specifies one of the bar code lengths for "Codabar Length Control" on page 
168. Length 2 is the maximum label length if in Variable Length Mode, or the second 
fixed length if in Fixed Length Mode. The length includes the bar code’s start, stop, 
check and data characters. The length must include at least one data character.
The length can be set from 3 to 50 characters. A setting of 00 specifies to ignore this 
length (only one fixed length). See 
"Set Length 2" on page 248 for more detailed pro-
gramming instructions.
Select Codabar Length 2 Setting
$CCBL2
To configure this feature, scan the ENTER/EXIT PRO-
GRAMMING MODE bar code above, then the bar 
code at left followed by the digits from the Alphanu-
meric characters in Appendix D, Keypad represent-
ing your desired character(s). End by scanning the 
ENTER/EXIT bar code again.
Make a mistake? Scan the CANCEL bar code to abort 
and not save the entry string. You can then start 
again at the beginning.
CANCEL
Length 2 = 50 (50 characters)