PLESSEY ENTER/EXIT PROGRAMMING MODE
PRODUCT REFERENCE GUIDE   
187
Plessey Set Length 1
This feature specifies one of the bar code lengths for "Plessey Length Control" on page 
186. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed 
length if in Fixed Length Mode. The length includes the bar code’s check and data char-
acters.
The length can be set from 1 to 50 characters. See "Set Length 1" on page 247 for more 
detailed programming instructions.
Plessey Set Length 2
This feature specifies one of the bar code lengths for "Plessey Length Control" on page 
186. Length 2 is the maximum label length if in Variable Length Mode, or the second 
fixed length if in Fixed Length Mode. The length includes the bar code’s check and data 
characters.
Length can be set from 1 to 50 characters. A setting of 00 specifies to ignore this length 
(only one fixed length). See 
"Set Length 2" on page 248 for more detailed programming 
instructions.
Select Plessey Length 1 Setting
$CPLL1
To configure this feature, scan the ENTER/EXIT PRO-
GRAMMING MODE bar code above, then the bar 
code at left followed by the digits from the Alphanu-
meric characters in Appendix D, Keypad represent-
ing your desired character(s). End by scanning the 
ENTER/EXIT bar code again.
Make a mistake? Scan the CANCEL bar code to abort 
and not save the entry string. You can then start 
again at the beginning.
CANCEL
Length 1 = 01 (one character)
Select Plessey Length 2 Setting
$CPLL2
To configure this feature, scan the ENTER/EXIT PRO-
GRAMMING MODE bar code above, then the bar 
code at left followed by the digits from the Alphanu-
meric characters in Appendix D, Keypad represent-
ing your desired character(s). End by scanning the 
ENTER/EXIT bar code again.
Make a mistake? Scan the CANCEL bar code to abort 
and not save the entry string. You can then start 
again at the beginning.
CANCEL