ENTER/EXIT PROGRAMMING MODE RS-232/USB-COM INTERFACES
46
GRYPHON™ I GD/GBT/GM4200
Disable Character
Specifies the value of the RS-232 host command used to disable the scanner.
ASCII characters or any hex value from 0 to 0xFF can be selected. See "Disable
Character" on page 226 for more detailed programming instructions.
Enable Character
Specifies the value of the RS-232 host command used to enable the scanner.
ASCII characters or any hex value from 0 to 0xFF can be selected. See "Enable
Character" on page 227for more detailed programming instructions
Setting to previously defined characters such as XON, XOFF, or host com-
mands conflicts with normal operation of these characters.
Select Disable Character Setting
$CR2DC
Make a mistake? Scan the CANCEL bar code to abort
and not save the entry string. You can then start again
at the beginning.
CANCEL
0x44 = Disable Character is ‘D’
Setting to previously defined characters such as XON, XOFF, or host com-
mands conflicts with normal operation of these characters.
Select Enable Character Setting
$CR2EC
Make a mistake? Scan the CANCEL bar code to abort
and not save the entry string. You can then start again
at the beginning.
CANCEL
0x45 = Enable Character is ‘E’