Symbologies Enter/Exit Programming Mode
Product Reference Guide
157
Codabar Minimum Reads
This feature specifies the minimum number of consecutive times a Codabar
label must be decoded before it is accepted as good read.
DEFAULT
Codabar Minimum Reads = 1
Codabar Minimum Reads = 2
Codabar Minimum Reads = 3
Codabar Minimum Reads = 4
$CCBMR01
$CCBMR02
$CCBMR03
$CCBMR04