Page #141 background image
Code 128
Code
Parameter
Description
I.D.#
Accept.
Input
Defaults Scanner Type
Min
Max
Factory
Laser
2D Imager
Lorax
Enter 1 for On and 0 for Off
Enable
Enables/disables the Code
128 symbology.
0408 On or Off Off On On
Enable
Aggressive
Decoding
Enables more aggressive
decoding algorithms to be
used in order to scan hard
to read labels.
0409 On or Off Off On Off
GS1-128
Enable
Enable GS1-128 variant of
Code 128 (independent of
Code 128).
040C On or Off Off On Off
Code 128 Ext.
ASCII Enable
Enable Extended ASCII
character conversion. This
enables the ability of Code
128 labels to use the
FNC4 character to encode
Extended ASCII
characters, as defined by
the latest Code 128
symbology specification.
040F On or Off Off On On
ISBT
Concatenation
Instructs the decoder to
concatenate Code 128
labels conforming to the
ISBT 128 standard.
040E On or Off Off Off Off
Minimum
Label
Length
Set the minimum label
length to be less than or
equal to maximum label
length.
0424 01 - 50 01 01 02
Maximum
Label
Length
This feature specifies the
maximum allowable length
of a Code 128 label. The
length includes check and
data characters. Maximum
Label Length should be
greater than or equal to
Minimum Label Length.
0425 01 - 50 01 50 20
Read
Verification
Sets the number of times a
label must be read before
it is transmitted.
0426 01 - 04 01 02 01

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic Lynx 00N0LD-1N0-MEN0 and is the answer not in the manual?

Datalogic Lynx 00N0LD-1N0-MEN0 Specifications

General IconGeneral
BrandDatalogic
ModelLynx 00N0LD-1N0-MEN0
CategoryPDA
LanguageEnglish

Related product manuals