EasyManuals Logo

Datalogic Lynx 00N0LD-1N0-MEN0 User Manual

Datalogic Lynx 00N0LD-1N0-MEN0
213 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #152 background imageLoading...
Page #152 background image
Matrix 2 of 5
Code
Parameter
Description
I.D.#
Accept.
Input
Defaults Scanner Type
Min
Max
Factory
Laser
2D Imager
Lorax
Enter 1 for On and 0 for Off
Enable
Enables/ disables the
Matrix 2 of 5 symbology.
0208 On or Off Off On Off
Enable
Aggressive
Decoding
Enables more aggressive
decoding algorithms to be
used in order to scan hard
to read labels.
0209 On or Off Off On Off
Enable
Checksum
Requires the use of
checksum characters to
verify a bar code.
020A On or Off Off Off Off
Send
Checksum
Instructs the terminal to
include the checksum in
the label transmission.
020B On or Off Off Off Off
Minimum
Label
Length
Set the minimum label
length to be less than or
equal to maximum label
length.
0224 01 - 50 01 01 06
Maximum
Label
Length
This feature specifies the
maximum allowable length
of a Matrix 2 of 5 label.
The length includes check
and data characters.
Maximum Label Length
should be greater than or
equal to Minimum Label
Length.
0225 01 - 50 01 50 10
Read
Verification
Sets the number of times a
label must be read before
it is transmitted.
0226 01 - 04 01 02 01
User ID
Specifies the symbology
identifier (if any) that is
sent by the decoder when
parameter Send Code ID
(Index 0025) is set to 3.
ASCII code zero (null) is
used to indicate that an
identifier is not to be sent
for the symbology.
0227
Any
single
ASCII
character
(00 = Off)
‘D’ ‘D’ ‘D’

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic Lynx 00N0LD-1N0-MEN0 and is the answer not in the manual?

Datalogic Lynx 00N0LD-1N0-MEN0 Specifications

General IconGeneral
BrandDatalogic
ModelLynx 00N0LD-1N0-MEN0
CategoryPDA
LanguageEnglish

Related product manuals