European Article Numbering-8 (EAN-8)
Code
Parameter
Description
I.D.#
Accept.
Input
Defaults Scanner Type
Min
Max
Factory
Laser
2D Imager
Lorax
Enter 1 for On and 0 for Off
Enable
Enables/disables the EAN-
8 symbology.
0518 On or Off Off On On
Enable
Aggressive
Decoding
Enables more aggressive
decoding algorithms to be
used in order to scan hard
to read labels.
0519 On or Off Off On Off
Send
Check Digit
Instructs the terminal to
include the check digit in
the label transmission.
051A On or Off Off On Off
Convert EAN-8
to EAN-13
Instructs the decoder to
expand EAN-8 labels to
their EAN-13 equivalents.
Any EAN-13 parameters
will then apply to the result.
051B On or Off Off On Off
Read
Verification
Sets the number of times a
label must be read before
it is transmitted.
0526 01 - 04 01 02 01
User ID
Specifies the symbology
identifier (if any) that is
sent by the decoder when
parameter Send Code ID
(Index 0025) is set to 3.
ASCII code zero (null) is
used to indicate that an
identifier is not to be sent
for the symbology.
0527
Any
single
ASCII
character
(00 = Off)
‘G’ ‘G’ ‘G’