GS1 DataBar Limited
Code
Parameter
Description
I.D.#
Accept.
Input
Defaults Scanner Type
Min
Max
Factory
Laser
2D Imager
Lorax
Enter 1 for On and 0 for Off
Enable
Enables/disables the GS1
DataBar Limited
symbology.
0808 On or Off Off On On
Convert to
UCC-EAN 128
Instructs the decoder to
transmit the label data as
one or more UCC-128
labels. The transmission
will use the UCC-128 AIM
identifier.
080C On or Off Off On Off
NOTE
If GS1 DataBar -14, GS1 DataBar -Expanded, GS1 DataBar -Limited, or GS1 DataBar –
Composite symbologies are enabled for UCC-EAN 128, then that setting is also enabled
for all other GS1 DataBar symbologies.
For the 2D Imager, GS1 DataBar -Expanded User Code ID is used for GS1 DataBar -14.