MicroPDF 417
Code
Parameter
Description
I.D.#
Accept.
Input
Defaults
Scanner
Type
Min
Max
Factory
2D Imager
Enter 1 for On and 0 for Off
MicroPDF-417
Enable
Enables/disables the
MicroPDF 417 symbology.
0A08 On or Off Off On Off
MicroPDF-417
Minimum
Set the minimum bar code
label length to be less
than or equal to maximum
label length.
0A24 1 - 366 1 366 1
MicroPDF-417
Maximum
This feature specifies the
maximum allowable length
of a label. The length
includes check and data
characters, if applicable.
Maximum Label Length
should be greater than or
equal to Minimum Label
Length.
0A25 1 - 366 1 366 366
MicroPDF-417
User
Code ID
Specifies the symbology
identifier (if any) that is
sent when parameter
Send Code ID (Index
0025) is set to 3. ASCII
code zero (null) is used to
indicate that an identifier
is not to be sent for the
symbology.
0A27
Any
single
ASCII
character
(00 = Off)
‘a’ ‘a’ ‘a’

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic Lynx 00N0LD-1N0-MEN0 and is the answer not in the manual?

Datalogic Lynx 00N0LD-1N0-MEN0 Specifications

General IconGeneral
BrandDatalogic
ModelLynx 00N0LD-1N0-MEN0
CategoryPDA
LanguageEnglish

Related product manuals