General Features
2-2 Magellan
®
1400i
1D Double Read Timeout — cont.
1D Label Gone Timeout
This feature sets the time after the last label segment is seen before the scanner prepares for a
new label.
START / END
PROGRAMMING BAR CODES
0.7 Second
0.8 Second
0.9 Second
1 Second
START / END
PROGRAMMING BAR CODES
Sets the label gone timeout duration using hex values from 000 to 255 in increments of ten milliseconds (10ms or 0.01 seconds). To
configure this feature, scan the “START/END” bar code above to place the unit in Programming Mode, then the “Set Label Gone Tim-
eout,” followed by three digits (zero padded) from the Alphanumeric table in
Appendix C, Alpha-Numeric Pad representing the
desired time value. Exit programming mode by scanning the “START/END” bar code again.
DEFAULT SETTING FOR THIS FEATURE: 200 milliseconds (020)