INTRODUCTION
23
2
Industrial Strength
Industrial compact 2D reader
Rugged full metal construction
Sealed circular connectors
IP67 protection class
50 °C max operating temperature
Supply voltage ranges from 10 to 30 Vdc
The reader is particularly suitable for industrial environments where protection against harsh
external conditions is required.
The reader is contained in an aluminum housing; with its internal illuminator, C-Mount lens
and protective cover, the mechanical dimensions are 123 x 60.5 x 87 mm and it weighs
about 482 g.
Electrical connection of Power, Host interfaces and I/O signals is provided through an M16
(IP67) 19-pin connector (Figure A, 9). A standard M12 D-Coded (IP67) Ethernet connector is