EasyManua.ls Logo

Datalogic Matrix 400 - 5 Matrix 400 Connector Electrical Connections; M16 19-Pin Connector

Datalogic Matrix 400
142 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
19-PIN CONNECTOR ELECTRICAL CONNECTIONS
63
5
5 MATRIX 400™ CONNECTOR ELECTRICAL CONNECTIONS
5.1 M16 19-PIN CONNECTOR
The Matrix 400™ reader is equipped with an M16 19-pin male connector (Binder, 423
Series) for connection to the power supply, serial interfaces and input/output signals. The
details of the connector pins are indicated in the following table:
Figure 73 – M16 19-pin Male Connector
19-pin M16 male connector pinout
Pin Name Function
A Vdc Power supply input voltage +
L GND Power supply input voltage -
K CHASSIS
Cable shield internally connected by capacitor to the
chassis
B I1A External Trigger A (polarity insensitive)
C I1B External Trigger B (polarity insensitive)
D I2A Input 2 A (polarity insensitive)
E I2B Input 2 B (polarity insensitive)
H O1+ Output 1 +
F O1- Output 1 -
G O2+ Output 2 +
I O2- Output 2 -
S RX Auxiliary RS232 RX
O TX Auxiliary RS232 TX
R ID+ ID-NET™ network +
P ID- ID-NET™ network -
Pin Name RS232
RS485
Full-Duplex
RS485
Half-Duplex
M TX TX+ RTX+
U RX *RX+
N RTS TX- RTX-
T
MAIN
INTERFACE
(SW
SELECTABLE)
CTS *RX-
* Do not leave floating, see par. 5.4.2 for connection details.
In order to meet EMC requirements:
connect the reader chassis to the plant earth ground by means of a flat copper braid
shorter than 100 mm;
connect the main interface cable shield to pin K of the 19-pin connector;