CODABAR ENTER/EXIT PROGRAMMING MODE
PRODUCT REFERENCE GUIDE   
173
Codabar Set Length 2
This feature specifies one of the bar code lengths for "Codabar Length Control" on page
172
. Length 2 is the maximum label length if in Variable Length Mode, or the second
fixed  length  if  in  Fixed  Length  Mode.  The  length  includes  the  bar  code’s  start,  stop,
check and data characters. The length must include at least one data character.
The length can be set from 3 to 50 characters. A setting of 00 specifies to ignore this
length (only one  fixed length). See  "
Set Length 2"  on page 302  for more detailed pro-
gramming instructions.
Select Codabar Length 2 Setting
$CCBL2
To configure this feature, scan the ENTER/EXIT PRO-
GRAMMING MODE bar code above, then the bar 
code at left followed by the digits from the Alphanu-
meric characters in Appendix D, Keypad represent-
ing your desired character(s). End by scanning the 
ENTER/EXIT bar code again.
Make a mistake? Scan the CANCEL bar code to abort 
and not save the entry string. You can then start 
again at the beginning.
CANCEL
Length 2 = 50 (50 characters)