ENTER/EXIT PROGRAMMING MODE DISPLAY AND KEYBOARD FEATURES
234
   POWERSCAN™ PD/PM96XX
DEFINE STRINGS
Configure string 1-5.
To configure this feature, scan the ENTER/EXIT PROGRAMMING MODE bar code at the
top of the page, then the bar code for the String you want to set. Define the label string
by scanning 32 digits from the Alphanumeric characters in 
Appendix D, Keypad.
The digits must be the  hexadecimal ASCII  representation of the desired characters; if
less than  the  expected string of  16  characters are selected, scan the  ENTER/EXIT bar
code to terminate the string.
End by scanning the ENTER/EXIT bar code again.
Set String 1
$CPWEP
$CPWEO
Set String 2
Set String 3
$CPWEA
$CPWEM
Set String 4
Set String 5
$CPWEL
Make a mistake? Scan the CANCEL bar code to abort 
and not save the entry string. You can then start 
again at the beginning.
CANCEL