Inthecaseofafailure...................whattodoif...?
Allergometerbikesundergoadetailedtestbeforetheyareshipped.ergo_bike
Shouldyou,inspiteofthis,faceafunctionalfailure,thefollowingrecommendationsshouldtellyouwhattodo.
Generalproceduretoidentifythecauseofafailure
Thebikesconsistessentiallyoftwofunctionalunits
-thedashboardandthedriveunit.
ergo_bike
Thedashboardcontainstheelectroniccircuitsusedforsystemcontrol,displayanddataprocessing.Thedashboard
andthedriveunitcommunicateviaacable,whichisroutedthroughthehandlebarscolumn,havingaconnectoronthe
dashboard,onthedriveunitandinthehandlebarscolumn.
Shouldtheassembledfailtofunction,thedefectwouldgenerallybefoundeitheronthedashboard,thedrive
unitorthecableconnectingthem.
ergo_bike
ergo_bike
Themostfrequentcauseofcomplaintturnsouttobejammingtheconnectingcableduringtheassembly
processofthe,ornotproperlypluggingthecableconnector.
Intheeventofafailure,checkcarefullyfirstif
Thecableconnectorlocatedonthelowerendofthehandlebarscolumnisproperlyconnected,andthatthecable
wasnotjammedorcutwhenthehandlebarscolumnwasmountedontotheframe.Todothisyouneedto
disassemblethehandlebarscolumn.
Thecablewasnotjammedorcutwhilemountingthedashboardonthehandlebarscolumn,orifthecableconnector
tothecircuitboardinsidethedashboardisloose.Todothisyouneedtodisassemblethedashboard.
Fasteningscrews
Contactingyourdealerortheservicedepartmentoftheergo_bike
Weneedthefollowinginformation:
1.The(thisnumberisonthesilverlabelontherearlowerpartoftheframe).devicenumber
3.The.proofofpurchaseandthedevicereferencesheet
4.ergometerbikeshaveabuilt-infailurediagnosticsystem,whichsignalsdevicefunctionalityusingared
andayellowLED.
TheseLEDsarelocatedbehindthetransparentsidecover(totherightsidelookinginthefrontdirection)intheupper
rightsectiononthecircuitboardofthedriveunit,andcanbeseenfromtheoutside(throughthegrid).Withthedevice
switchedon,theyellowLEDshouldblinkwhenpedallingslowly,andblinkfasterwhenpedallingfast.
ergo_bike
Withthedeviceswitchedon,theredLEDshouldlightwithhighintensitywhenpedallingagainstalowload,and
decreaseinintensityastheloadincreases.
PleaseinformusofthestatusoftheseLEDsforallcomplaintsconcerning“thedeviceisnotbrakingor“thedeviceis
notbrakingproperly.Thisenablesustodrawrelativelyconcreteconclusionsaboutthecauseofthefailure.
Ifyouwishtoobtainmoreinformationonyourdevice,pleasevisitourserviceandrepairhintswebsiteonInternet
().Youcanalsocallourserviceandrepairhotline
(telephonenumber++49/(0)911/97536-0).
www.daum-electronic.de
Thedriveunitislocatedinsidethedevice,behindthesaddlecolumn.Itcontainsthepowersupply,theeddycurrent
brakeandtherelatedelectroniccircuits.
Allthefasteningscrewsmustbetightenedfromtimetotime.Werecommendtighteningthematleastafterthefirst
50kmandthenonceevery500km.
2.The(youcanaccessthisnumberunderthe“Menu”,“Information”,“VersionData”,
"SerialNumberonthegraphicdisplay).
dashboardversionnumber
Ifthecauseofthefailurecouldnotbeidentified,youshouldcontactyourdealerortherepairhotlineof
daumelectronicgmbh(telephonenumber++49/(0)911/97536-0).