EasyManuals Logo

Davis Instruments Vantage Pro2 User Manual

Default Icon
56 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #23 background imageLoading...
Page #23 background image
Selecting Units of Measure
20
Temperature may be displayed in degrees Fahrenheit (ºF) or Celsius
(ºC). Temperatures can also be displayed in degrees or in tenths of a
degree.
2. Press TEMP again to select inside temperature.
Each consecutive press of TEMP displays temperature readings for any optional
temperature, temperature/humidity, soil temperature, soil moisture stations also con-
nected to your console. The order of the optional sensors readings display depends
on your station configuration. Temperatures for temperature stations display, with
soil temperature and moisture stations displaying consecutively.
Humidity
Press HUM to select outside humidity. Pressing HUM a second time selects
inside humidity. Humidity is displayed in percent relative humidity. Each consecutive
press of HUM displays humidity readings for any optional humidity, leaf wetness, and
leaf temperature stations also connected to your console. The order of the optional sen-
sors readings display depends on your station configuration. Humidity readings for
humidity stations display, with leaf wetness and leaf temperature readings displaying
consecutively.
Wind Chill
Press 2ND then press CHILL to select Wind Chill. Wind Chill is
displayed in either Fahrenheit (ºF) or Celsius (ºC) in whole
degrees.
The console uses the ten-minute average wind speed to calculate wind chill.
Dew Point
Press 2ND then press DEW to select Dew Point. Dew Point is dis-
played in either Fahrenheit (ºF) or Celsius (ºC) in whole degrees.
Barometric Pressure
Press BAR to select barometric pressure. Barometric pressure may be displayed in
inches (in), millimeters (mm), millibars (mb) or hectoPascals (hPa).
TEMP
N
W
NE
SE
SW
Vertical Scale: X10
WIND
RAIN YEAR
in
TEMP OUT
HUM IN
HUM OUT
DAILY RAIN
in
TEMP IN
hPa
BAROMETER
STATION NO.1
F
F
F
MPH
Last 24 hrs
hr
Every 1
S
E
NW
pm
HEAT INDEX
HUM OUT
HUM IN
CHILL
F
DEW POINT
F
hPa
BAROMETER
Humidity, Pressure, Dew Point & Wind
HUM
DEW
2
ND
WIND
CHILL
2
ND
HUM
DEW
BAR

Other manuals for Davis Instruments Vantage Pro2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Davis Instruments Vantage Pro2 and is the answer not in the manual?

Davis Instruments Vantage Pro2 Specifications

General IconGeneral
Update Interval2.5 seconds
Wind Direction Resolution
Wind Direction Range0 to 360°
Rain CollectorSelf-emptying tipping bucket
UV Index Range0 to 16
Solar Radiation Range0 to 1800 W/m²
Console DisplayLCD with backlight
Wireless Transmission Range1000 feet (300 meters) line of sight
Temperature Range-40 to 150 °F (-40 to 65 °C)
Humidity Range1 to 100%
Barometric Pressure Range16.00 to 32.50 inHg (540 to 1100 hPa)
Wind Speed Range0 to 200 mph (0 to 322 km/h)
Rain Collector Size0.01 inch (0.2 mm) resolution
Rain Measurement Accuracy±4% at rates up to 2 in/hr (50 mm/hr)
Power SupplySolar-powered with battery backup
Console Power SupplyAC adapter or 3 C batteries

Related product manuals