Auto Start (1000-9000, default=4000) is the RPM that
must be reached before the unit will go active and be
able to make corrections. If the Starting RPM is set
to 5000 RPM, then the unit is active and monitoring
the engine, but not making any corrections until the
Auto Start RPM is reached. Once the Auto Start
RPM is reached, the unit will make corrections as
needed above the Minimum RPM.
Minimum RPM (1000-9000, default=2000) sets the
RPM below which the TC is not able to make a
correction. This prevents unwanted correction at
low RPM, even if slip is detected.
Minimum RPM (1000-9000, default=10,000) sets the
RPM above which the TC is not able to make a
correction. This may be useful to stop the unit from
making corrections at the end of the strait, even if
the tires are slipping.
End Time (0-10, default=3) is used to return the unit
back to waiting mode if the engine drops below the
Minimum RPM for the duration of the End Time
setting.
Mid RPM (1000-9000, default=10,000) sets the RPM
where the Max Retard will begin to degrade with
RPM. This allows for a smaller correction at higher
RPM. Set to same as Max RPM to disable.