50
4  Downloading/uploading data memory
4.1  Downloading data to an external memory unit (DOWNLOAD)
1.  Scroll down the parameters with 
 and   keys until you visualize P011;
2.  Press the   key, the display visualizes the word “ ” ashing;
3.  Press the   again and continue pressing it for 5 sec (if you release it before this period, the procedure is stopped);
4.  Release the   key as soon as the word “ ” stops ashing;
All the control panel congurations (TYPE, parameters, remotes, operators stroke, etc..) are saved in the external memory unit;
Warning: If there is any data in the external memory, during the memory download they will be overwritten.
5.  At the end of the operation display returns to P011.
4.2  Uploading data from an external memory unit (UPLOAD)
1.  Scroll down the parameters with 
 and   keys until you visualize P012;
2.  Press the 
 key, the display visualizes the word “ ” ashing;
3.  Press the   again and continue pressing for 5 sec (if you release it before this period, the procedure is stopped);
4.  Release the 
 key as soon as the word “ ” stops ashing;
All the control panel congurations (TYPE, parameters, remotes, operators stroke, etc..) contained in the external memory unit are 
uploaded in the connected control panel;
5.  At the end of the operation display returns to P012.
WARNING If you are not connected to any external storage units or if the connecting cable is disconnected during the data transfer 
operation, the display will visualize  , then the control unit is entirely reset and the display shows the word “TYPE” ashing. 
Refer to the instruction of the external memory card to restore the operation of the control panel.
5 Inputs conguration
Where the installation requires different commands and / or additional to 
the standard ones  described by plan,  you can congure  each input for the 
operation desired (eg START, PHOTOS, STOP, etc ...).
1.  Scroll down the parameters with the 
 and   to see that corresponding 
to the desired one:
  ●  P017=for INPUT 1;
  ●  P018=for INPUT 2;
  ●  P019=for INPUT 3;
  ●  P020=for INPUT 4;
  ●  P021=for INPUT 5;
  ●  P022=for INPUT 6;
2.  Conrm  by pressing on the   key to get access to the parameter (eg. 
P018);
3.  Scroll down with the   and  , keys to set the value corresponding to 
the desired operation (refer to table “Input Conguration parameters” on 
page 54);
4.  Conrm by pressing on the   key (display shows again P018).
5.  Execute the new connection to the input just recongured.
6 Programming complete
WARNING At the end of the programming procedure, use the buttons   and   until the appearance of the symbol “----”, the operator 
is now ready again for new manoeuvres.