PROGRAMMING PROCEDURES
Positioning of operator 1
Positioning of operator 2
Memorization of the motors’ stroke
Deletion of transmitters
Transmitters memorizing
Search and deletion of a transmitter
Restoring the operating parameters
Lock access to programming
How to learn connected DE@NET devices (unused at the moment)
Restoring the “I/O” congurations (input/output)
Downloading data on the external memory unit
Uploading data  from an external memory unit
Visualisation of inputs and operations-counter status
Unused parameter
Unused parameter
PAR. PARAMETER DESCRIPTION
SETTABLE VALUES
DEFAULT VALUES
(for different standards of installation)
TYPE
00
TYPE
01
TYPE
02
TYPE 
03
TYPE
04
INPUTS CONFIGURATION PARAMETERS
INPUT_3  selectioning input type
• 000: IN3 type=free contact
• 001: IN3 type=constant resistance 8K2
INPUT_1  operating selection
• 000: NONE (unused parameter)
• 001: START (start)
• 002: PED. (pedestrian)
• 003: OPEN (separated open)
• 004: CLOSE (separated close)
• 005: OPEN_PM (man present open)
• 006: CLOSE_PM (man present close)
• 007: ELOCK-IN (electric-lock activation. See P062)
• 008: PHOTO 1 (photocell 1)
• 009: PHOTO 2 (photocell 2)
• 010: SAFETY 1 (safety rib 1)
• 011: STOP (lock) / SAS INPUT (with NET_EXP only)
• 012: FCA1 (opening limit switches Mot1)
• 013: FCA2 (opening limit switchtes Mot2)
• 014: FCC1 (closing limit switches Mot1)
• 015: FCC2 (closing limit switches Mot2)
• 016: SAFETY 2 (safety rib 2)
• 017: OPEN_INT (with NET_EXP only)
• 018: OPEN_EXT (with NET_EXP only)
• 019: AUX_IN (with NET_EXP only)
• 020: SAFETY INHIBITION (SAFETY inhibition)
IN1
INPUT_2  operating selection
INPUT_3  operating selection
INPUT_4  operating selection
INPUT_5  operating selection
INPUT_6  operating selection