OPERATING PARAMETERS
SAFETY 1
Operation of the SFT input: if = 0 safety edge always enabled, if = 1 safety edge enabled only
while closing, if = 2 safety edge enabled only while closing and before any movement, if = 3
safety edge enabled only when opening, if = 4 safety edge enabled only while opening and
before any movement; as for the obstacle detection with internal anti-crushing sensor, also the
activation of the inputs SFT1 and SFT2 causes the complete or partial reversal as set by P055
(duration of inversion on obstacles while opening, and P056 (duration of reversal on obstacle
while closing)
• 000: “safety edge always enabled
• 001: “safety edge enabled only while closing
• 002: “safety edge enabled only while closing and before any
movement
• 003: “safety edge enabled only when opening
• 004: “safety edge enabled only while opening and before any
movement
SAFETY 2
Delay on limit switch detection: the operation is stopped after 1,5 sec from limit switch detection. When
during this delay a stop is detected, the operator is suddenly stopped
• 000: “limit switch delay disabled
• 001: “limit switch delay enabled
Adjustment of acceleration durability
Warning: if soft start is activated, the acceleration is deactivated indipendently from P070 value.
• 000: “acceleration deactivated (it runs an acceleration of
minimum durability, almost imperceptible)
• 00X: “adjusts the acceleration durability at 1,5 sec (X*6 ms)
Safeties self-test: if = 0 24V output with autotest disabled; if = 1 24V output for safeties with self-test
(it turn the output off and check the contact opening before each maneuver).
Attention: In order to work in self-test mode, all devices must be connected to the stabilized output 24V_ST
(33-34), and be wired and aligned before the motor stroke learning (P003).
• 000: “net power supply (safeties self-test disabled)
• 001: “safeties self-test enabled
Activation of SAS function (with NET_EXP only): SAS output is connected to an input STOP / SAS INPUT of a
second control panel, causing the operation “trap man” (disabling the opening of the second door as long as
the rst is not completely closed).
If this parameter is enabled after a reset, it performs an automatic RESP during which the SAS output is not
activated. If limit switches are present and they are crushed after a reset, the RESP is not executed.
Warning: if both doors are manually unlocked and moved from the closed position creates the interlock
condition. You will then need to manually close at least one of the two doors.
• 000: “SAS function” deactivated
• 001: “SAS function” activated
Unused parameter
Unused parameter
Unused parameter
Unused parameter
Electronic brake (TYPE 00 ONLY):
The control circuit drives the motor in a way to generate a braking force at every stop.
Warning: Function available only with functioning at motor 1 with encoder.
• 000: “deactivated
• 001: “activated
Conguration parameters dedicated to the expansion card NET_EXP (for a detailed description of the
parameters, refer to the instruction manual).