 WARNING Check that there is a switch or an omni polar magneto-thermal circuit bre-
aker that enables complete disconnection in case of over voltage category III conditions 
installed upstream from the power system.
 WARNING To ensure an appropriate level of electrical safety  always keep the 230V 
power supply cables apart (minimum  4mm in the open or 1 mm through insulation) from 
low voltage cables (motors power supply, controls, electric locks, aerial  and auxiliary 
circuits power supply), and fasten the latter with appropriate clamps near the terminal 
boards.
 WARNING If the power cable is damaged, it must be replaced by the manufacturer or 
its technical assistance service or, in any case, by a person with similar qualications to 
prevent any risk.
 WARNING All installation, maintenance, cleaning or repair operations on any part of 
the system must be performed exclusively by qualied personnel with the power supply 
disconnected working in strict compliance with the electrical standards and regulations 
in force in the nation of installation.
Cleaning and maintenance destined to be performed by the user must not be performed 
by unsupervised children.
 WARNING Using spare parts not indicated by DEA System and/or incorrect re-assem-
bly can create risk to people, animals and property and also damage the product. For this 
reason, always use only the parts indicated by DEA System and scrupulously follow all 
assembly instructions.
 WARNING  Changing the closing intensity could lead to dangerous situations. Therefore, 
qualied personnel should only perform increases to the closing force. After adjustment, 
compliance with regulatory limits values should be detected with a force impact-mea-
suring instrument. The sensitivity  of  the  obstacle detection  may be adjusted gradually 
to the door (see programming instructions). The anti-crushing device operation must be 
checked  after each manual adjustment.  Manual  modication  of  the force can only  be 
done by qualied personnel by performing the measurement test according to EN 12445. 
Modications to the force adjustment must be documented in the machine manual.
 WARNING  The compliance of the  internal sensing obstacles device  to  requirements 
of EN12453 is guaranteed only if used in conjunction with motors tted with encoders.
 WARNING Any external security devices used for compliance with the limits of impact 
forces must be conform to standard EN12978.
WARNING  In compliance with EU Directive 2012/19/EU on waste electrical and elec-
tronic equipment (WEEE), this electrical product should not be treated as municipal 
mixed waste. Please dispose of the product and bring it to the collection for an appropri-
ate local municipal recycling.