V0614, 1.15
CN6: Pins 25 - 32
Digital Outputs (4x)
Voltage
Current
ON state
20-28 V DC
0.5 A max.
OFF state
-
0.1 mA max. (leakage current)
Digital Inputs (4x)
Voltage
Current
ON state
9-28 V DC
20mA max.
OFF state
0 - 4 V DC
1 mA max.
Notes:
The sum of all output currents should not exceed 10A.
All digital outputs are short-circuit proof.
To guarantee a defined state during power on or off, the load of the outputs should
comply with IEC 61131.