V0614, 2.34
The signals are divided in four groups. Each group can be opened or closed, in order to
examine one group more closely. The value of all recorded signals is shown in the text box,
which can be placed left or right with the <tab> key.
The following groups are shown:
analog output signals
analog input signals
digital output signals
digital input signals
For the meaning of all signals we refer to the Delem machine parameter manual, where all
signals are described in detail.
Remarks:
If cycle files must be kept for further analysis, it is recommended to store them in non-
volatile memory. For instance, when the ‘new’ command is first used to create a file, the
directory \Temp is offered. This directory is lost when the control is switched off! To keep
the files on a permanent medium, store the cycle files on the control hard disk or a USB
disk. See also section 2.2 for more information about directories.
The cycle files are automatically given the extension ‘.frd’ and can be read on any control
that is equipped with this analysis software. They can also be sent to Delem if more
support is necessary.