ES30 and FS15 hardware specifications
Note
All ratings assume a fully configured ES30 or FS15.
Table 28 ES30 and FS15 hardware specifications
Specification Description
AC line voltage 100 to 240 Vac ± 10%, single-phase, 47 to 63
Hz
AC line current (operating maximum) 2.8 A max at 100 Vac, 1.4 A max at 200 Vac
Power consumption (operating maximum) 280 VA (235 W) max
Power factor 0.98 min at full load, low voltage
Heat dissipation (operating maximum) 8.46 x 10
5
J/hr, (800 Btu/hr) max
Dimensions (rack mounted, with bezel)
l
Width: 17.62" (45 cm) Depth: 14”
(35.56cm)
l
Height: 5.25” (13.34cm) 3 RU
Maximum Weight 68 lbs (30.8 kg)
Operating Temperature
l
Ambient temperature: 10
o
C to 35
o
C (50
o
F to 95
o
F)
l
Temperature gradient: 10
o
C/hr (180
o
F/hr)
l
Relative humidity extremes: 20% to 80%
noncondensing
Recommended Operating Relative Humidity 40% to 55% noncondensing
Non-Operating Temperature
l
Ambient temperature: -40
o
C to 65
o
C
(-40
o
F to 149
o
F)
l
Temperature gradient: 25
o
C/hr
(45
o
F/hr)
l
Relative humidity: 10% to 90%
noncondensing
Hardware Specifications
130 Data Domain ES30 Expansion Shelf and FS15 SSD Shelf Hardware Guide

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell EMC Data Domain FS15 SSD Shelf and is the answer not in the manual?

Dell EMC Data Domain FS15 SSD Shelf Specifications

General IconGeneral
BrandDell EMC
ModelData Domain FS15 SSD Shelf
CategoryStorage
LanguageEnglish

Related product manuals