1
. Check the service LED on the affected power supply unit.
NOTE:
If a power supply unit is found to be faulted, the service required LED is a solid amber.
2. L
og in as sysadmin.
3. Enter the alerts show current command to display messages indicating power supply failure. A sample output is
shown.
# a
lerts show current
Id Post Time Severity Class Object Message
-- ---------------------- -------- --------- --------- -----------------
22 Tue May 3 18:46:56 2016 CRITICAL HWFailure Encl=1:PowerSupply=1 EVT-
ENVIRONMENT-00026:
Power supply has
failed
4. Enter the enclosure show powersupply command to check the status of each power supply.
# e
nclosure show powersupply
This command may take up to a minute to complete. Please wait...
--------- ----------- ------- ------
Enclosure Description Status
--------- -------------- -------
1 Power module 0 OK
1 Power module 1 FAILED
--------- -------------- -------
Field Replaceable Units 25