Figure 40. Install the system board
1
touch point (2) 2 screw (8)
3 system board
Next steps
1 If required, install the Trusted Platform Module (TPM). See, the Installing the Trusted Platform Module section.
2 Reinstall the following components:
a expansion card riser
b memory modules
c heat sink and processor
d cooling shroud
e iDRAC port card, if removed
3 Reconnect all cables to the system board.
NOTE
: Ensure that the cables inside the system are routed through the cable routing latch.
4 Follow the procedure listed in the After working inside your system section.
5 Import your new or existing iDRAC Enterprise license. For more information, see the Integrated Dell Remote Access Controller User’s
Guide, at Dell.com/idracmanuals.
Installing and removing system components
95