3. Remove the drive backplane cover.
4. If installed, remove the air shroud.
Steps
1. Align and slide the left control panel in the slot on the system.
2. Connect the left control panel cable to the connector on the system board and secure it using cable latch.
3. Route the left control panel cable through the side wall of the system and slide the cable into the clip.
NOTE: Route the cable properly to prevent the cable from being pinched or crimped.
4. Using the Phillips #1 screwdriver, tighten the screws to secure the left control panel to the system.
Figure 136. Installing the left control panel
Next steps
1. Install the drive backplane cover.
2. If applicable, install the air shroud.
3. Follow the procedure listed in After working inside your system.