Next steps
1. If removed, install the air shroud.
2. Follow the procedure listed in the After working inside your system.
Removing the liquid cooling module
Prerequisites
1. Follow the safety guidelines listed in the Safety instructions.
2. Follow the procedure listed in the Before working inside your system.
WARNING: The heat sink and processor are hot to touch for some time after the system has been powered off.
Allow the heat sink and processor to cool down before handling them.
Steps
1. Using a Phillips #1 screwdriver, loosen the captive screw on the liquid cooling ring holder.
2. Lift up the liquid cooling ring holder to loosen the liquid cooling tubes.
3. Disconnect the liquid cooling detection cable from the rear I/O (RIO) card connector.
4. Unlatch the tube clip to loosen the liquid cooling tubes.
5. Remove the liquid cooling tubes from the RIO panel.
6. Using a Torx #T30 screwdriver, loosen the captive screws on the heat sink.
7. Set all the anti-tilt wires to unlocked position (inward position).
8. Lift the liquid cooling heat sink modules from the system.
NOTE: The numbers on the image do not depict the exact steps. The numbers are for representation of sequence.
Figure 67. Removing the liquid cooling heat sink modules
80
Installing and removing system components