Feature Detailed Description
ACT (Data transmission):
Blinking green — activity.
Off — no activity.
Console port
LNK (Link speed):
Off — no link.
Solid green — link.
Management port
LNK (Link speed):
Off — no link.
Solid green — link on 1 G speed.
Solid amber — link on 100 M or 10 M speeds.
ACT (Data transmission):
Blinking green — activity.
Off — no activity.
Stack number
Displays the stack unit number of the switch.
Displays 1 if switch is not part of a stack.
Temperature
Solid green — system temperature is below threshold limit.
Solid red — system temperature has exceeded the threshold
limit of 75°C.
PSU 1 and 2
Off — power failure or no power.
Solid green — normal operation.
Blinking green — locator function is enabled.
System status
Solid green — normal operation. The CLI prompt is available.
Blinking green — boot-up in progress.
Solid red — critical system error.
Blinking red — noncritical system error (fan fail, power supply
fail).
Fan
Solid green — fan is powered and running at the expected rpm.
Solid red — fan failed.
M (Master)
Solid green — system is in Stacking Master mode.
Off — switch is in Slave mode.
SFP+ (10G) port
LNK (Link speed):
Off — no link.
Solid green — link on 10 G speed.
Solid amber — link on 1 G speed.
ACT (Data transmission):
Off — no link.
Blinking green — activity.