Installing System Components 83
If the drive has been online, the green 
activity/
fault indicator will flash as 
the drive is powered down. When the drive indicators are off, the drive is 
ready for removal.
 
3 Press the button on the front of the drive carrier and open the drive 
carrier release handle to release the drive. See 
Figure 3-5
.
4
Slide the hard drive out until it is free of the drive bay.
  CAUTION: To maintain proper system cooling, all empty hard-drive bays must 
have drive blanks installed. 
5
Insert a drive blank in the vacated drive bay. See "Installing a Hard-Drive 
Blank."
6
If applicable, install the bezel. See "Installing the Front Bezel."
Installing a Hot-Swap Hard Drive
  CAUTION: When installing a hard drive, ensure that the adjacent drives are fully 
installed. Inserting a hard-drive carrier and attempting to lock its handle next to a 
partially installed carrier can damage the partially installed carrier's shield spring 
and make it unusable. 
 
CAUTION: To prevent data loss, ensure that your operating system supports hot-
swap drive installation. See the documentation supplied with your operating 
system. 
1 If present, remove the front bezel. See 
"Removing the Front Bezel."
2
If a drive blank is present in the bay, remove it. See "Removing a Hard-
Drive Blank."