PowerEdge T610 Technical Guide 39
o The remaining hard drives must be 3.5" hard drives and must be either all SAS or
all SATA
• Solid state drives (SSDs) require the PERC 6/i (PERC H700) integrated storage controller and
cannot be mixed with any other type of hard drive
12.2.1 Hard Disk Drive Carriers
The T610 supports the Dell 2.5" and 3.5" hard drive carriers.
See Figure 9.
Dell 2.5” Hard Drive Carrier Figure 9.
12.2.2 Empty Drive Bays
For the slots that are not occupied by drives, a carrier blank is provided to maintain proper cooling,
maintain a uniform appearance to the unit, and provide EMI shielding.
The T610 does not support diskless configuration.
12.2.3 Hard Drive LED Indicators
Each disk drive carrier has two LED indicators visible from the front of the system. One is a green LED
for disk activity and the other is a bicolor (green/amber) LED for status information. The activity LED
is driven by the disk drive during normal operation. The bicolor LED is controlled by the storage
enclosure processor (SEP) device on the backplane. Both LEDs are used to indicate certain conditions
under direction of a storage controller.
For more information, see the Hard-Drive Indicator Patterns section in the About Your System chapter
in the Dell PowerEdge T610 Systems Hardware Owner’s Manual on Support.Dell.com.
12.3 RAID Configurations
See Table 12 for information on factory RAID configurations. For information on additional
configurations, visit Dell.com.