4. Information button
In AUTO, manual or o mode, successive presses on the i buon enable you to:
- nd out the room temperature or the setpoint temperature (depending on the conguration
during installation (menu 2-04),
- show the boiler/heat pump operating hours meter, as well as the number of days remaining
before maintenance (if this seing is on, menu 2-07),
Viewing this screen temporarily cancels the display of the symbol until the maintenance due date.
5. Time setting
6. Adjusting temperature settings
h(ON)
023
4
5
Operating hours meter (boiler/
heat pump).
Measured
temperature
Setpoint
temperature
Time to boiler/heat pump
maintenance
Return to automatic
mode
1
1
0
0
2021...
1
2
3
4
5
8
9
10
11
12
6
7
EXIT
Turn the dial to .
-> Set the day, month, year with + or -.
Conrm with OK.
-> Set the hour then the minutes with + or -.
Conrm with OK.
To exit the mode, turn the dial.
Turn the dial to
.
The Comfort setpoint temperature
ashes.
Press + or - to adjust, then
press OK to conrm and go to the
next seing.
❹ -> Repeat the operations
to adjust the Economy and Frost
protection temperatures.
To exit the mode, turn the dial.
5°C
30°C
5°C
30°C
5°C
16°C
2
3
4
5
6
7
8
EXIT
1
Comfort (from 5°C to 30°C)
Economy (from 5°C to 30°C)
Frost protection (5°C to 16°C)
- If the Comfort temperature is controlled by each radiator (menu 1-08 = 1), you can only set Economy and Frost
protection temperatures.
- The temperature seings may be restricted (menu 2-01 = 1).