3
~1,50 m
Mini 20 cm
PROG x 1
PROG x 7
32145
RLN CT
Th
NL
32145
RLN CT
NL
Ø max. 1,5 mm²
OFF
ON
1. Installing the transmitter
1.1 Location
The thermostat can be wall-mounted in a room
where the temperature is to be regulated from,
at a recommended height of 1.5m and away from
any heat sources (replace, direct sunlight, etc.)
or draughts (window, door, etc.).
To avoid unwanted air movements that would
distort the sensor measurement, the wire entry
into the ush-mounted box must be plugged
(mastic, glass wool, etc.).
IMPORTANT: Do not install the thermostat on a
wall in contact with the outside or with an
unheated room (e.g. garage, etc.).
1.2 Mounting/Connection
❶ Switch o the power to your setup.
❷ Separate the box from its base.
❸ Connect and secure the base. Your Tybox
must be connected with exible or rigid cables
with a maximum cross-section of 1.5 mm².
❹ Toggle the switch to choose the programme
type: weekly (A) or daily (B).
❺ ❻ Close and lock the box.
❼ Turn on the power to your setup.
Thermostat input control
Circulator control
INSTALLATION