Chapter 5  Trial Run and Tuning Procedure|ASDA-A&A+ Series 
5-12    
Revision April 2009 
The position command is selected by POS0 ~ POS2. Please refer to the following table: 
Position 
Command 
POS2  POS1  POS0  CTRG Parameters
Moving Speed 
Register 
Description 
P1-15  Rotation No. (+/- 30000)
Internal 
Position 1 
0 0 0 
 
P1-16 
P2-36 (V1) 
Pulse No. (+/- max cnt) 
P1-17  Rotation No. (+/- 30000)
Internal 
Position 2 
0 0 1 
 
P1-18 
P2-37 (V2) 
Pulse No. (+/- max cnt) 
P1-19  Rotation No. (+/- 30000)
Internal 
Position 3 
0 1 0 
 
P1-20 
P2-38 (V3) 
Pulse No. (+/- max cnt) 
P1-21  Rotation No. (+/- 30000)
Internal 
Position 4 
0 1 1 
 
P1-22 
P2-39 (V4) 
Pulse No. (+/- max cnt) 
P1-23  Rotation No. (+/- 30000)
Internal 
Position 5 
1 0 0 
 
P1-24 
P2-40 (V5) 
Pulse No. (+/- max cnt) 
P1-25  Rotation No. (+/- 30000)
Internal 
Position 6 
1 0 1 
 
P1-26 
P2-41 (V6) 
Pulse No. (+/- max cnt) 
P1-27  Rotation No. (+/- 30000)
Internal 
Position 7 
1 1 0 
 
P1-28 
P2-42 (V7) 
Pulse No. (+/- max cnt) 
P1-29  Rotation No. (+/- 30000)
Internal 
Position 8 
1 1 1 
 
P1-30 
P2-43 (V8) 
Pulse No. (+/- max cnt) 
0: indicates OFF (Normally Open); 1: indicates ON (Normally Closed)  
The users can set the value of these 8 groups of commands (P1-15 ~ P1-30) freely. The command can be 
absolute position command (P1-33 =0) or relative position command (P1-33 =1). 
For example:  
Set P1-33 to 1 (Absolute position command) 
(The new setting will be effective after the servo drive is restarted (after switching power 
off and on)) 
Set P1-15 to 1 (rotation number) 
Set P1-16 to 0 (pulse number) 
The command of internal position 1: P1-15 Rotation No. + P1-16 Pulse No. 
Set P1-17 to 10 (rotation number) 
Set P1-18 to 0 (pulse number) 
The command of internal position 2: P1-17 Rotation No. + P1-18 Pulse No. 
Set P1-19 to -10 (rotation number) 
Set P1-20 to 0 (pulse number) 
The command of internal position 3: P1-19 Rotation No. + P1-20 Pulse No. 
Set P1-21 to 100 (rotation number) 
Set P1-22 to 0 (pulse number) 
The command of internal position 4: P1-21 Rotation No. + P1-22 Pulse No. 
Set P1-23 to -1000 (rotation number) 
Set P1-24 to 0 (pulse number) 
The command of internal position 5: P1-23 Rotation No. + P1-24 Pulse No. 