Chapter 7 Servo Parameters|ASDA-A&A+ Series 
Revision April 2009    7-89 
P4 - 22    SAO  Analog Speed Input Offset  Communication Addr.: 0416H
Default: 0  Related Section: N/A 
Applicable Control Mode: S   
Unit: mV 
Range: -5000~5000 
Settings: 
In speed mode, the users can use this parameter to adjust analog speed input offset value 
manually. Before using this function, please short the internal circuit first or connecting to a 0V 
output of the external controller in advance, and then use this parameter to adjust analog speed 
input offset value. 
 
P4 - 23    TAO  Analog Torque Input Offset  Communication Addr.: 0417H
Default: 0  Related Section: N/A 
Applicable Control Mode: T   
Unit: mV 
Range: -5000~5000 
Settings: 
In torque mode, the users can use this parameter to adjust analog torque input offset value 
manually. Before using this function, please short the internal circuit first or connecting to a 0V 
output of the external controller in advance, and then use this parameter to adjust analog torque 
input offset value. 
 
P4 - 24 
 
Reserved  Communication Addr.: 0418H
 
P4 - 25 
 
Reserved  Communication Addr.: 0419H
 
P4 - 26 
 
Reserved  Communication Addr.: 041AH
 
 
 
 
 