Chapter 4 Parameters|
Revision Nov. 2008, VLE1, SW V1.03 4-35
01-24
01-25
01-26
01-27
Frequency
Time
01-29 Switch Frequency for S3/S4 Changes to S5 Unit: 0.01
Control
mode
VF VFPG SVC FOCPG FOCPM
Factory setting: 0.00
Settings 0.00~120.00Hz
It is used to set the switch frequency between S4 and S5 for smooth stop.
It is recommended to set this parameter to the leveling speed of elevator.
Frequenc
01-12
accel. time
01-13
decel. time
Time
01-25=S2
01-26=S3
01-24=S1
01-27=S4
01-30=S5
01-29
Switch frequency
for S3/S4 changes
to S5
01-28
Mode Selection when Frequency< Fmin
Control
mode
VF VFPG SVC
Factory setting: 0
Settings 0 Output Waiting
1
Zero-speed operation
2
Fmin (4th output frequency setting)
When the AC motor drive is at 0Hz, it will operate by this parameter.
When it is set to 1 or 2, voltage will be output by Fmin corresponding output voltage.
01-31
Deceleration Time when Operating without RUN
Command
Unit: 0.01
Control
mode
VF VFPG SVC FOCPG FOCPM
Factory setting: 2.00
Settings 0.00~600.00 Sec