Power PMAC Clipper User Manual
Specifications 16
Environmental Specifications
Specification
Description
Range
Ambient operating Temperature
EN50178 Class 3K3 IEC721-3-3
Minimum operating temperature
0°C (32°F)
Maximum operating temperature
45°C (113°F)
Storage Temperature Range
EN 50178 Class 1K4 IEC721-3-1/2
Minimum Storage temperature
-25°C (-13°F)
Maximum Storage temperature
70°C (158°F)
Humidity Characteristics with
NO condensation and NO formation of ice
IEC721-3-3
Minimum Relative Humidity
5% HU
Maximum Relative Humidity
up to 35°C (95°F)
95% HU
Maximum Relative Humidity
from 35°C up to 50°C (122°F)
85% HU
De-rating for Altitude
0 ~ 1000m (0 ~ 3300ft)
No de-rating
1000 ~ 3000m (3300 ~ 9840ft)
-0.01%/m
3000 ~ 4000m (9840 ~ 13000ft)
-0.02%/m
Environment
ISA 71-04
Degree 2 environments
Atmospheric Pressure
EN50178 class 2K3
70 KPa to 106 KPa
Shock
Unspecified
Vibration
Unspecified
Air Flow Clearances
3" (76.2mm) above and below unit for air flow
Cooling
Natural convection and built-in CPU fan
Standard IP Protection
IP20
IP 55 can be evaluated for custom applications

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta Tau Power PMAC Clipper and is the answer not in the manual?

Delta Tau Power PMAC Clipper Specifications

General IconGeneral
BrandDelta Tau
ModelPower PMAC Clipper
CategoryController
LanguageEnglish

Related product manuals