ASDA-A2 Chapter 6 Control Mode of Operation
Revision February, 2017 6-47
6.4.3 Smooth Torque Command
Related parameters:
P1-07 TFLT Analog Torque Command (Low-pass Filter)
Address: 010EH
010FH
Operational
Interface
Panel / Software Communication
Related Section:
6.4.3
Default
0
Control
Mode
T
Unit
ms
Range
0 ~ 1000 (0: disable this function)
Data Size
16-bit
Format
Decimal
Settings
0: Disabled
TFLT
Ta r g e t S p ee d
6.4.4 The Scaling of Analog Command
The motor torque command is controlled by the analog voltage deviation between T_REF and
GND and goes with parameter P1-41 to adjust the torque slope and its range.