ASDA-A2 Chapter 8 Parameters
Revision February, 2017 8-91
P2-xx Extension Parameters
P2-00 KPP Position Loop Gain
Address: 0200H
0201H
Operational
Interface
Panel / Software Communication
Related Section:
6.2.8
Default
35
Control
Mode
PTPR
Unit
rad/s
Range
0 ~ 2047
Data Size
16-bit
Format
Decimal
Settings
When the value of position loop gain is increased, the position
response can be enhanced and the position error can be reduced. If
the value is set too big, it may easily cause vibration and noise.
P2-01 PPR Switching Rate of Position Loop Gain
Address: 0202H
0203H
Operational
Interface
Panel / Software Communication
Related Section:
6.2.8
Default
100
Control
Mode
PTPR
Unit
%
Range
10 ~ 500
Data Size
16-bit
Format
Decimal
Settings
Switch the changing rate of position loop gain according to the gain-
switching condition.