ASDA-A2 Chapter 8 Parameters
Revision February, 2017 8-157
P4-18 COF4
Current Detector (W2 Phase) Offset
Adjustment
Address: 0424H
0425H
Operational
Interface
Panel / Software Communication
Related Section: -
Default
Factory default
Control
Mode
ALL
Unit
-
Range
0 ~ 32767
Data Size
16-bit
Format
Decimal
Settings
Manually adjust the hardware offset. The adjustment function needs to
be enabled by the setting of parameter P2-08. It is not suggested to
adjust the auxiliary adjustment. This parameter cannot be reset.
P4-19 TIGB
IGBT NTC Adjustment Detection Level
(cannot reset)
Address: 0426H
0427H
Operational
Interface
Panel / Software Communication
Related Section: -
Default
Factory default
Control
Mode
ALL
Unit
-
Range
1 ~ 4
Data Size
16-bit
Format
Decimal
Settings
Please cool down the drive to 25 Celsius degree when adjusting