ASDA-A2 Chapter 3 Wiring
Revision February, 2017 3-43
Pulse command can be input by the way of open-collector or Line driver. The maximum input pulse
of Line driver is 500 kpps and 200 kpps for open-collector.
C3-1: The source of pulse input is open-collector NPN equipment which applies the internal
power of the servo drive.
C3-2: The source of pulse input is open-collector PNP equipment which applies the internal
power of the servo drive.
NOTE
Resistor of 1K(1w) has to be connected.