ASDA-A2 Chapter 8 Parameters
Revision February, 2017 8-117
P2-50 DCLR Pulse Clear Mode
Address: 0264H
0265H
Operational
Interface:
Panel / Software Communication
Related Section: -
Default:
0
Control
Mode:
PT
Unit:
-
Range:
0x0 ~ 0x1
Data Size:
16-bit
Format:
Hexadecimal
Settings:
Please refer to table 8.1 for digital input setting.
When set digital input (DI) as CCLR, the function of pulse clear is
effective. Clear the position error (It is applicable in PT, PR mode).
If this DI is ON, the accumulative position error will be cleared to 0.
0: The triggering method of CCLR is rising-edge.
1: The triggering method of CCLR is level.
P2-51 Reserved
P2-52â–² IDXS Indexing Coordinates Scale
Address: 0268H
0269H
Operational
Interface:
Panel/Software Communication
Related Section:
Default:
1000000000
Control
Mode:
ALL
Unit:
PUU
18 350
19 300
1A 250
1B 200
1C 175
1D 150
1E 125
1F 100

Table of Contents

Other manuals for Delta ASD-A2-2043 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta ASD-A2-2043 Series and is the answer not in the manual?

Delta ASD-A2-2043 Series Specifications

General IconGeneral
BrandDelta
ModelASD-A2-2043 Series
CategoryServo Drives
LanguageEnglish

Related product manuals