EasyManua.ls Logo

Delta ASD-A2-2043 Series - Page 399

Delta ASD-A2-2043 Series
721 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 8 Parameters ASDA-A2
8-148 Revision February, 2017
P4-02
ASH3 Fault Record (N-2)
Address: 0404H
0405H
Operational
Interface
Panel / Software Communication
Related Section:
4.4.1
Default
0
Control
Mode
ALL
Unit
-
Range
-
Data Size
32-bit
Format
Hexadecimal
Settings
The last third abnormal status record
Low word: LXXXX: display ALM number
High word: hYYYY: display the error code corresponds to CANopen /
DMCNET
P4-03
ASH4 Fault Record (N-3)
Address: 0406H
0407H
Operational
Interface
Panel / Software Communication
Related Section:
4.4.1
Default
0
Control
Mode
ALL
Unit
-
Range
-
Data Size
32-bit
Format
Hexadecimal
Settings
The last fourth abnormal status record
Low word: LXXXX: display ALM number
High word: hYYYY: display the error code corresponds to CANopen /
DMCNET