Chapter 6  Control Modes of Operation  ASDA-B2 
6-18     Revision May, 2018 
P1-36    TSL 
Acceleration / Deceleration Constant of  
S-curve 
Address: 0148H 
0149H 
 
Operation 
Interface: 
Panel/Software   Communication  
Related Section: 
Section 6.3.3 
 
Default: 0 
 
Control 
Mode: 
S 
 
Unit: ms 
 
Range: 0 ~ 10000 (0: Disabled) 
 
Data Size: 16-bit 
 
Display 
Format: 
Decimal 
Settings:  Acceleration / Deceleration Constant of S-Curve: 
 
 
P1-34: Set the acceleration time of acceleration / deceleration of 
trapezoid-curve 
P1-35: Set the deceleration time of acceleration / deceleration of 
trapezoid-curve 
P1-36: Set the smoothing time of S-curve acceleration and 
deceleration 
P1-34, P1-35, and P1-36 can be set individually. 
NOTE
 
When the source of speed command is analog, and P1-36 is set 
to 0, it will disable S-curve function. 
Analog Speed Command Filter 
Analog speed command filter is provided especially for ASDA-B2 series users.  
It mainly helps with buffer when the analog input signal changes too fast. 
Speed (rpm)
3000
-3000
0
132465798
Time (sec)
Motor Torque
Analog speed command