Page #261 background image
Chapter 8 Parameters ASDA-M
8-30
Revision December, 2014
P0-35 MAP1A
Target Setting of Mapping Parameter
P0-25
Address: 0046H
0047H
Parameter
Attribute
Parameter for individual axis
Related Section:
Section 4.3.5
Operational
Interface
Panel / Software Communication
Default
0x0
Control
Mode
ALL
Unit
-
Range
determined by the communication
address of the parameter group
Data Size
32bit
Format
HEX
Settings
Select the data block to access the parameter corresponded by
register 1.
The mapping content is 32 bits wide and can map to two 16-bit
parameters or one 32-bit parameter.
P0-35:
Mapping parameter: P0-35; Mapping content: P0-25.
When PHPL, it means the content of P0-25 includes two 16-bit
parameters.
VH=*(PH)VL=*(PL)
Mapping parameter: P0-35; Mapping content: P0-25.