Chapter 8 Parameters ASDA-M
8-82 Revision December, 2014
P2-06 KVI Speed Integral Compensation
Address: 020CH
020DH
Parameter
Attribute
Parameter for individual axis
Related Section:
Section 6.3.6
Operational
Interface
Panel / Software Communication
Default
100
Control
Mode
ALL
Unit
rad/s
Range
0 ~ 1023
Data Size
16bit
Format
DEC
Settings
Increasing the value of speed integral compensation can enhance
speed response and diminish the deviation of speed control.
However, if the value is set too big, it would easily cause
resonance and noise.
P2-07 KVF Speed Feed Forward Gain
Address: 020EH
020FH
Parameter
Attribute
Parameter for individual axis
Related Section:
Section 6.3.6
Operational
Interface
Panel / Software Communication
Default
0
Control
Mode
ALL
Unit
%
Range
0 ~ 100
Data Size
16bit
Format
DEC
Settings
When the speed control command runs smoothly, increasing the
gain value can reduce the speed command error. If the command
does not run smoothly, decreasing the gain value can reduce the
mechanical vibration during operation.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta ASD-M-0721 Series and is the answer not in the manual?

Delta ASD-M-0721 Series Specifications

General IconGeneral
BrandDelta
ModelASD-M-0721 Series
CategoryServo Drives
LanguageEnglish

Related product manuals