Chapter 8 Parameters ASDA-M
8-84 Revision December, 2014
P2-09 DRT DI Debouncing Time
Address: 0212H
0213H
Parameter
Attribute
Parameter for individual axis
Related Section: -
Operational
Interface
Panel / Software Communication
Default
2
Control
Mode
ALL
Unit
2ms
Range
0 ~ 20
Data Size
16bit
Format
DEC
Example
4 = 8 ms
Settings
When the environmental noise is big, increasing the setting value
can enhance the control stability. However, if the value is set too
big, the response time will be influenced.
P2-10 DI1 DI1 Functional Planning
Address: 0214H
0215H
Parameter
Attribute
Parameter for individual axis
Related Section:
Table 8.1
Operational
Interface
Panel / Software Communication
Default
101
Control
Mode
ALL
Unit
-
Range
0 ~ 0x315F (the last two codes are DI
code)
Data Size
16bit
Format
HEX